Clinical and Hemodynamic Effects of Percutaneous Edge-to-Edge Mitral Valve Repair in Atrial Versus Ventricular Functional Mitral Regurgitation

Am J Cardiol. 2021 Dec 15:161:70-75. doi: 10.1016/j.amjcard.2021.08.062.

Abstract

The present study aims to assess the clinical and hemodynamic impact of percutaneous edge-to-edge mitral valve repair with MitraClip in patients with atrial functional mitral regurgitation (A-FMR) compared with ventricular functional mitral regurgitation (V-FMR). Mitral regurgitation (MR) grade, functional status (New York Heart Association class), and major adverse cardiac events (MACE; all-cause mortality or hospitalization for heart failure) were evaluated in 52 patients with A-FMR and in 307 patients with V-FMR. In 56 patients, hemodynamic assessment during exercise echocardiography was performed before and 6 months after intervention. MR reduction after MitraClip implantation was noninferior in A-FMR compared with V-FMR (MR grade ≤2 at 6 months in 94% vs 82%, respectively, p <0.001 for noninferiority) and was associated with improvement of functional status (New York Heart Association class ≤2 at 6 months in 90% vs 80%, respectively, p = 0.2). Hemodynamic assessment revealed that cardiac output at 6 months was higher in A-FMR at rest (5.1 ± 1.5 L/min vs 3.8 ± 1.5 L/min, p = 0.002) and during peak exercise (7.9 ± 2.4 L/min vs 6.1 ± 2.1 L/min, p = 0.02). In addition, the reduction in systolic pulmonary artery pressure at rest was more pronounced in A-FMR: Δ SPAP -13.1 ± 15.1 mm Hg versus -2.2 ± 13.3 mm Hg (p = 0.03). MACE rate at follow-up was significantly lower in A-FMR versus V-FMR, with an adjusted odds ratio of 0.46 (95% confidence interval 0.24 to 0.88), which was caused by a reduction in hospitalization for heart failure. In conclusion, percutaneous edge-to-edge mitral valve repair with MitraClip is at least as effective in A-FMR as in V-FMR in reducing MR. However, the hemodynamic improvement and reduction of MACE were significantly better in A-FMR.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Cardiac Catheterization / methods*
  • Echocardiography
  • Female
  • Follow-Up Studies
  • Heart Valve Prosthesis Implantation / methods*
  • Heart Ventricles / diagnostic imaging
  • Heart Ventricles / physiopathology*
  • Hemodynamics / physiology*
  • Humans
  • Male
  • Mitral Valve / diagnostic imaging
  • Mitral Valve / physiopathology
  • Mitral Valve / surgery*
  • Mitral Valve Insufficiency / diagnosis
  • Mitral Valve Insufficiency / physiopathology
  • Mitral Valve Insufficiency / surgery*
  • Retrospective Studies
  • Treatment Outcome