Polymer-free Biolimus-A9 coated thin strut stents for patients at high bleeding risk 1-year results from the LEADERS FREE III study

Catheter Cardiovasc Interv. 2022 Feb;99(3):593-600. doi: 10.1002/ccd.29869. Epub 2021 Jul 9.

Abstract

Background: In patients at high bleeding risk (HBR), the LEADERS FREE (LF) trial established the safety and efficacy of a polymer-free drug coated (Biolimus-A9) stainless steel stent (SS-DCS) with 30 days of dual antiplatelet treatment (DAPT). In LEADERS FREE III, we studied a new cobalt-chromium thin-strut stent (CoCr-DCS) in HBR patients.

Methods: The CoCr-DCS shares all of the design features of the SS-DCS but has a CoCr stent platform with strut thickness of 84-88 μm. The primary safety endpoint was a composite of cardiac death, myocardial infarction (MI), and definite/probable stent thrombosis. The primary efficacy endpoint was clinically indicated target lesion revascularization. Outcomes were compared to those of LF (non-inferiority to SS-DCS for safety and superiority to SS-BMS for efficacy). Additional propensity-matched comparisons were performed to account for baseline differences.

Results: We recruited 401 HBR patients using identical criteria to the LF trial. At 1 year, the primary safety endpoint was reached by 31/401 (8.0%) of patients treated with the CoCr-DCS versus 35/401 (8.9%) for the propensity-matched cohort (HR: 0.89, [0.55-1.44], p < 0.001 for non-inferiority, 0.62 for superiority). The efficacy endpoint was reached by 16/401 (4.2%) of CoCr-DCS patients versus 41/401 (10.6%) in the propensity-matched cohort (HR: 0.4 [0.2:0.7]) (p = 0.007 for superiority). There was no statistical difference between CoCr-DCS and SS-DCS in terms of efficacy (HR: 1.46 [0.68-3.15], p = 0.33).

Conclusions: The new thin-strut CoCr-DCS proved non-inferior to the SS-DCS for safety, and superior to the BMS for efficacy in HBR patients treated with 30 days of DAPT.

Keywords: CLIN-clinical trials; DES-stent; PCI-percutaneous coronary intervention (PCI); drug eluting.

Publication types

  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Coronary Artery Disease* / diagnostic imaging
  • Coronary Artery Disease* / etiology
  • Coronary Artery Disease* / therapy
  • Drug-Eluting Stents* / adverse effects
  • Humans
  • Percutaneous Coronary Intervention* / adverse effects
  • Percutaneous Coronary Intervention* / methods
  • Polymers
  • Prosthesis Design
  • Risk Factors
  • Stents / adverse effects
  • Treatment Outcome

Substances

  • Polymers