Computed tomography derived predictors of permanent pacemaker implantation after transcatheter aortic valve replacement: A meta-analysis

Catheter Cardiovasc Interv. 2021 Nov 15;98(6):E897-E907. doi: 10.1002/ccd.29805. Epub 2021 Jun 2.

Abstract

Objectives: This meta-analysis sought to assess predictors of permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with focus on preprocedural multi-slice computed tomography (MSCT) derived data.

Background: Transcatheter aortic valve replacement (TAVR) has expanded to a well-established treatment for severe symptomatic aortic stenosis at high and intermediate surgical risk. PPI after TAVR remains one of the most frequent procedure-related complications and appears to be influenced by several factors.

Methods: The authors conducted a literature search in PubMed/MEDLINE and EMBASE databases to identify studies that investigated preprocedural MSCT data and the rate of PPI following TAVR with new-generation devices.

Results: Ten observational studies (n = 2707) met inclusion criteria for the final analysis. PPI was performed in 387 patients (14.3%) after TAVR. Patients requiring PPI had a larger annulus perimeter (MD: 1.66 mm; p < .001) and a shorter membranous septum length (MD: -1.1 mm; p < .05). Concerning calcification distribution, patients with requirement for new pacemaker implantation showed increased calcification of the left coronary cusp (MD: 47.6 mm3 ; p < .001), and the total left ventricular outflow tract (MD: 24.42 mm3 ; p < .01). Lower implantation depth (MD: 0.95 mm; p < .05) and oversizing (MD: 1.52%; p < .05) were procedural predictors of PPI following TAVR.

Conclusions: Besides the well-known impact of electrocardiographic and procedure-related factors on conduction disturbances, MSCT derived distribution of the aortic valve and left ventricular outflow tract calcification, as well as membranous septum length, are associated with an increased risk of PPI following TAVR.

Keywords: ECG; TAVR; calcification; computed tomography; conduction disorder; membranous septum.

Publication types

  • Meta-Analysis
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aortic Valve / diagnostic imaging
  • Aortic Valve / surgery
  • Aortic Valve Stenosis* / diagnostic imaging
  • Aortic Valve Stenosis* / surgery
  • Heart Valve Prosthesis*
  • Humans
  • Multidetector Computed Tomography
  • Pacemaker, Artificial*
  • Risk Factors
  • Tomography, X-Ray Computed
  • Transcatheter Aortic Valve Replacement* / adverse effects
  • Treatment Outcome