Elsevier

JACC: Cardiovascular Imaging

Volume 14, Issue 11, November 2021, Pages 2107-2119
JACC: Cardiovascular Imaging

Original Research
Prognostic Value of Pulmonary Transit Time and Pulmonary Blood Volume Estimation Using Myocardial Perfusion CMR

https://doi.org/10.1016/j.jcmg.2021.03.029Get rights and content
Under a Creative Commons license
open access

Abstract

Objectives

The purpose of this study was to explore the prognostic significance of PTT and PBVi using an automated, inline method of estimation using CMR.

Background

Pulmonary transit time (PTT) and pulmonary blood volume index (PBVi) (the product of PTT and cardiac index), are quantitative biomarkers of cardiopulmonary status. The development of cardiovascular magnetic resonance (CMR) quantitative perfusion mapping permits their automated derivation, facilitating clinical adoption.

Methods

In this retrospective 2-center study of patients referred for clinical myocardial perfusion assessment using CMR, analysis of right and left ventricular cavity arterial input function curves from first pass perfusion was performed automatically (incorporating artificial intelligence techniques), allowing estimation of PTT and subsequent derivation of PBVi. Association with major adverse cardiovascular events (MACE) and all-cause mortality were evaluated using Cox proportional hazard models, after adjusting for comorbidities and CMR parameters.

Results

A total of 985 patients (67% men, median age 62 years [interquartile range (IQR): 52 to 71 years]) were included, with median left ventricular ejection fraction (LVEF) of 62% (IQR: 54% to 69%). PTT increased with age, male sex, atrial fibrillation, and left atrial area, and reduced with LVEF, heart rate, diabetes, and hypertension (model r2 = 0.57). Over a median follow-up period of 28.6 months (IQR: 22.6 to 35.7 months), MACE occurred in 61 (6.2%) patients. After adjusting for prognostic factors, both PTT and PBVi independently predicted MACE, but not all-cause mortality. There was no association between cardiac index and MACE. For every 1 × SD (2.39-s) increase in PTT, the adjusted hazard ratio for MACE was 1.43 (95% confidence interval [CI]: 1.10 to 1.85; p = 0.007). The adjusted hazard ratio for 1 × SD (118 ml/m2) increase in PBVi was 1.42 (95% CI: 1.13 to 1.78; p = 0.002).

Conclusions

Pulmonary transit time (and its derived parameter pulmonary blood volume index), measured automatically without user interaction as part of CMR perfusion mapping, independently predicted adverse cardiovascular outcomes. These biomarkers may offer additional insights into cardiopulmonary function beyond conventional predictors including ejection fraction.

Key Words

first pass perfusion
outcomes
pulmonary blood volume

Abbreviations and Acronyms

AIF
arterial input function
CI
confidence interval
ICD
implantable cardioverter-defibrillator
IQR
interquartile range
MBF
myocardial blood flow
MPR
myocardial perfusion reserve
PBV
pulmonary blood volume
PTT
pulmonary transit time
PTTn
pulmonary transit time normalized for heart rate

Cited by (0)

The authors attest they are in compliance with human studies committees and animal welfare regulations of the authors’ institutions and Food and Drug Administration guidelines, including patient consent where appropriate. For more information, visit the Author Center.

Drs Manisty and Kellman contributed equally to this work as joint senior authors.