1-Year Results From the RANGER II SFA Randomized Trial of the Ranger Drug-Coated Balloon

JACC Cardiovasc Interv. 2021 May 24;14(10):1123-1133. doi: 10.1016/j.jcin.2021.03.021.

Abstract

Objectives: This study sought to evaluate the safety and effectiveness of the Ranger drug-coated balloon (DCB) (paclitaxel dose density 2 μg/mm2) for treating superficial femoral artery or proximal popliteal artery lesions.

Background: Paclitaxel-coated balloon treatment prevents reinterventions, but dose and coating characteristics differ among balloons and necessitate discrete confirmation of safety and effectiveness.

Methods: Patients with symptomatic lower limb ischemia (Rutherford classification 2 to 4) were randomized 3:1 to treatment with the Ranger DCB or standard percutaneous transluminal angioplasty (PTA). Twelve-month primary target lesion patency, freedom from major adverse events (i.e., target lesion revascularization, major amputations, death within 1 month of the index procedure), and patient outcomes were analyzed.

Results: Mean lesion length was 82.5 ± 48.9 mm for the Ranger DCB group (n = 278) and 79.9 ± 49.3 mm for the control group (n = 98). Ranger DCB was superior to PTA (82.9% [n = 194 of 234] vs. 66.3% [n = 57 of 86]) with observed 12-month primary patency rates yielding a difference of 16.6% (95% confidence interval: 5.5% to 27.7%; p = 0.0013). Noninferior freedom from major adverse events (94.1% [n = 241 of 256] vs. 83.5% [n = 76 of 91]) was demonstrated with a difference of 10.6% (95% confidence interval: 2.5% to 18.8%; noninferiority p < 0.0001). Primary patency rate curves showed significant separation by Kaplan-Meier analysis (log-rank p = 0.0005), with rates of 89.8% and 74.0% estimated at day 365 for the Ranger DCB and PTA cohorts, respectively.

Conclusions: The low-dose Ranger DCB demonstrated significantly better effectiveness than standard PTA through 1 year and a good safety profile. (Ranger™ Paclitaxel Coated Balloon vs Standard Balloon Angioplasty [RANGER II SFA]; NCT03064126).

Keywords: drug-coated balloon; paclitaxel; peripheral arterial disease; superficial femoral artery; vascular patency.

Publication types

  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Angioplasty, Balloon* / adverse effects
  • Coated Materials, Biocompatible
  • Femoral Artery / diagnostic imaging
  • Humans
  • Paclitaxel / adverse effects
  • Peripheral Arterial Disease* / diagnostic imaging
  • Peripheral Arterial Disease* / therapy
  • Pharmaceutical Preparations*
  • Popliteal Artery / diagnostic imaging
  • Prospective Studies
  • Time Factors
  • Treatment Outcome
  • Vascular Patency

Substances

  • Coated Materials, Biocompatible
  • Pharmaceutical Preparations
  • Paclitaxel

Associated data

  • ClinicalTrials.gov/NCT03064126