Totally peripheral approach for ICD lead vegetation removal in a GUCH patient

J Cardiovasc Electrophysiol. 2021 Jun;32(6):1778-1781. doi: 10.1111/jce.15032. Epub 2021 May 12.

Abstract

AngioVac system (AngioDynamics) has already proved to be a useful tool in the treatment of thrombotic and endocarditic formations concerning the venous district. Herein, the AngioVac aspiration system combined with the bidirectional rotational Evolution mechanical sheath lead extraction was used for an effective and safety cardiac-device-related-infective-endocarditis removal in a grown-up congenital heart disease patient through a totally peripheral approach.

Keywords: AngioVac system; GUCH patient; cardiac-device-related-infective-endocarditis; implantable cardioverter defibrillator; lead extraction.

Publication types

  • Case Reports

MeSH terms

  • Defibrillators, Implantable* / adverse effects
  • Device Removal
  • Endocarditis*
  • Humans
  • Thrombosis*