Association of Hospital Procedural Volume With Outcomes of Percutaneous Left Atrial Appendage Occlusion

JACC Cardiovasc Interv. 2021 Mar 8;14(5):554-561. doi: 10.1016/j.jcin.2020.11.029. Epub 2021 Mar 1.

Abstract

Objectives: The aim of this study was to examine the association between percutaneous left atrial appendage occlusion (LAAO) procedural volume and in-hospital outcomes.

Background: Several studies have demonstrated an inverse volume-outcome relationship for patients undergoing invasive cardiac procedures. Whether a similar association exists for percutaneous LAAO remains unknown.

Methods: Patients undergoing LAAO in 2017 were identified in the Nationwide Readmissions Database. Hospitals were categorized into 3 groups on the basis of tertiles of annual procedural volume: low (5 to 15 cases/year), medium (17 to 31 cases/year), and high (32 to 211 cases/year). Multivariate hierarchical logistic regression and restricted cubic spline analyses were performed to examine the association of hospital LAAO volume and outcomes. The primary outcome was in-hospital major adverse events (MAE), defined as a composite of mortality, stroke or transient ischemic attack, bleeding or transfusion, vascular complications, myocardial infarction, systemic embolization, and pericardial effusion or tamponade requiring pericardiocentesis or surgery.

Results: This study included 5,949 LAAO procedures performed across 196 hospitals with a median annual procedural volume of 41 (interquartile range: 25 to 67). Low-volume hospitals had higher rates of in-hospital MAE (9.5% vs. 5.6%; p < 0.001), stroke or transient ischemic attack (2.1% vs. 1.3%; p = 0.049), and bleeding or transfusion (6.1% vs. 3.5%; p = 0.002) compared with high-volume hospitals. No differences were noted for other components of MAE and index length of stay. On multivariate analysis, higher procedural volume was associated with lower rates of in-hospital MAE, with an adjusted odds ratio for medium versus low volume of 0.69 (95% confidence interval: 0.46 to 1.04; p = 0.08) and for high versus low volume of 0.55 (95% confidence interval: 0.37 to 0.82; p = 0.003).

Conclusions: Higher hospital procedural volume is associated with better outcomes for LAAO procedures. Further studies are needed to determine if this relationship persists for long-term outcomes.

Keywords: Watchman; hospital volume; left atrial appendage occlusion; outcomes.

MeSH terms

  • Atrial Appendage* / diagnostic imaging
  • Atrial Fibrillation* / diagnostic imaging
  • Atrial Fibrillation* / therapy
  • Hospitals, Low-Volume
  • Humans
  • Stroke* / etiology
  • Treatment Outcome