Tilt testing remains a valuable asset

Eur Heart J. 2021 May 1;42(17):1654-1660. doi: 10.1093/eurheartj/ehab084.

Abstract

Head-up tilt test (TT) has been used for >50 years to study heart rate/blood pressure adaptation to positional changes, to model responses to haemorrhage, to assess orthostatic hypotension, and to evaluate haemodynamic and neuroendocrine responses in congestive heart failure, autonomic dysfunction, and hypertension. During these studies, some subjects experienced syncope due to vasovagal reflex. As a result, tilt testing was incorporated into clinical assessment of syncope when the origin was unknown. Subsequently, clinical experience supports the diagnostic value of TT. This is highlighted in evidence-based professional practice guidelines, which provide advice for TT methodology and interpretation, while concurrently identifying its limitations. Thus, TT remains a valuable clinical asset, one that has added importantly to the appreciation of pathophysiology of syncope/collapse and, thereby, has improved care of syncopal patients.

Keywords: Active stand; ECG-loop recorders; Orthostatic hypotension; Postural orthostatic tachycardia syndrome; Psychogenic pseudosyncope; Syncope; Tilt-table test; Vasovagal syncope.

Publication types

  • Research Support, N.I.H., Extramural
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Autonomic Nervous System Diseases*
  • Heart Rate
  • Humans
  • Hypotension, Orthostatic* / diagnosis
  • Syncope / diagnosis
  • Syncope / etiology
  • Tilt-Table Test