3-Year Outcomes of the ULTIMATE Trial Comparing Intravascular Ultrasound Versus Angiography-Guided Drug-Eluting Stent Implantation

JACC Cardiovasc Interv. 2021 Feb 8;14(3):247-257. doi: 10.1016/j.jcin.2020.10.001. Epub 2020 Oct 29.

Abstract

Objectives: The aim of this study was to explore the difference in target vessel failure (TVF) 3 years after intravascular ultrasound (IVUS) guidance versus angiographic guidance among all comers undergoing second-generation drug-eluting stent (DES) implantation.

Background: The multicenter randomized ULTIMATE (Intravascular Ultrasound Guided Drug Eluting Stents Implantation in "All-Comers" Coronary Lesions) trial showed a lower incidence of 1-year TVF after IVUS-guided DES implantation among all comers compared with angiographic guidance. However, the 3-year clinical outcomes of the ULTIMATE trial remain unknown.

Methods: A total of 1,448 all comers undergoing DES implantation who were randomly assigned to either IVUS guidance or angiographic guidance in the ULTIMATE trial were followed for 3 years. The primary endpoint was the risk for TVF at 3 years. The safety endpoint was definite or probable stent thrombosis (ST).

Results: At 3 years, TVF occurred in 47 patients (6.6%) in the IVUS-guided group and in 76 patients (10.7%) in the angiography-guided group (p = 0.01), driven mainly by the decrease in clinically driven target vessel revascularization (4.5% vs. 6.9%; p = 0.05). The rate of definite or probable ST was 0.1% in the IVUS-guided group and 1.1% in the angiography-guided group (p = 0.02). Notably, the IVUS-defined optimal procedure was associated with a significant reduction in 3-year TVF relative to that with the suboptimal procedure.

Conclusions: IVUS-guided DES implantation was associated with significantly lower rates of TVF and ST during 3-year follow-up among all comers, particularly those who underwent the IVUS-defined optimal procedure compared with those with angiographic guidance. (Intravascular Ultrasound Guided Drug Eluting Stents Implantation in "All-Comers" Coronary Lesions; NCT02215915).

Keywords: all-comers; drug-eluting stent; intravascular ultrasound; target vessel failure.

Publication types

  • Comparative Study
  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Coronary Angiography
  • Coronary Artery Disease*
  • Drug-Eluting Stents*
  • Humans
  • Percutaneous Coronary Intervention
  • Treatment Outcome
  • Ultrasonography, Interventional

Associated data