Modified wire atrial septostomy with a reverse transseptal puncture in an infant: Case report

Catheter Cardiovasc Interv. 2021 Apr 1;97(5):865-868. doi: 10.1002/ccd.29514. Epub 2021 Feb 4.

Abstract

We report a modified technique of wire atrial septostomy (WAS) with a reverse transseptal puncture (TSP) in an infant case of pulmonary atresia with intact ventricular septum. A radiofrequency (RF) wire was advanced to the septum through a 4 Fr pigtail catheter hooked on the left side of atrial septum and RF energy was applied while advancing the wire across the septum. Following that reverse TSP, WAS was performed to cut the septal tissue using a 0.010 microwire and RF wire. The atrial septum defect (ASD) was enlarged to a size of 15 mm. WAS with a reverse TSP could be a useful and safe method to enlarge ASD in infants with congenital heart diseases.

Keywords: microwire; pulmonary atresia with intact ventricular septum; radiofrequency wire; reverse transseptal puncture; wire atrial septostomy.

Publication types

  • Case Reports

MeSH terms

  • Atrial Septum* / diagnostic imaging
  • Atrial Septum* / surgery
  • Catheter Ablation*
  • Heart Septal Defects, Atrial* / diagnostic imaging
  • Heart Septal Defects, Atrial* / surgery
  • Humans
  • Infant
  • Punctures
  • Treatment Outcome