Sutureless versus conventional bioprostheses for aortic valve replacement in severe symptomatic aortic valve stenosis

J Thorac Cardiovasc Surg. 2021 Mar;161(3):920-932. doi: 10.1016/j.jtcvs.2020.11.162. Epub 2020 Dec 14.

Abstract

Objective: Sutureless aortic valves are a novel option for aortic valve replacement. We sought to demonstrate noninferiority of sutureless versus standard bioprostheses in severe symptomatic aortic stenosis.

Methods: The Perceval Sutureless Implant Versus Standard-Aortic Valve Replacement is a prospective, randomized, adaptive, open-label trial. Patients were randomized (March 2016 to September 2018) to aortic valve replacement with a sutureless or stented valve using conventional or minimally invasive approach. Primary outcome was freedom from major adverse cerebral and cardiovascular events (composite of all-cause death, myocardial infarction, stroke, or valve reintervention) at 1 year.

Results: At 47 centers (12 countries), 910 patients were randomized to sutureless (n = 453) or conventional stented (n = 457) valves; mean ages were 75.4 ± 5.6 and 75.0 ± 6.1 years, and 50.1% and 44.9% were female, respectively. Mean ± standard deviation Society of Thoracic Surgeons scores were 2.4 ± 1.7 and 2.1 ± 1.3, and a ministernotomy approach was used in 50.4% and 47.3%, respectively. Concomitant procedures were performed with similar rates in both groups. Noninferiority was demonstrated for major adverse cerebral and cardiovascular events at 1 year, whereas aortic valve hemodynamics improved equally in both groups. Use of sutureless valves significantly reduced surgical times (mean extracorporeal circulation times: 71.0 ± 34.1 minutes vs 87.8 ± 33.9 minutes; mean crossclamp times: 48.5 ± 24.7 vs 65.2 ± 23.6; both P < .0001), but resulted in a higher rate of pacemaker implantation (11.1% vs 3.6% at 1 year). Incidences of perivalvular and central leak were similar.

Conclusions: Sutureless valves were noninferior to stented valves with respect to major adverse cerebral and cardiovascular events at 1 year in patients undergoing aortic valve replacement (alone or with coronary artery bypass grafting). This suggests that sutureless valves should be considered as part of a comprehensive valve program.

Keywords: aortic valve replacement; randomized controlled trial; sutureless.

Publication types

  • Comparative Study
  • Equivalence Trial
  • Multicenter Study
  • Webcast

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve / diagnostic imaging
  • Aortic Valve / physiopathology
  • Aortic Valve / surgery*
  • Aortic Valve Stenosis / diagnostic imaging
  • Aortic Valve Stenosis / mortality
  • Aortic Valve Stenosis / physiopathology
  • Aortic Valve Stenosis / surgery*
  • Bioprosthesis*
  • Female
  • Heart Valve Prosthesis Implantation / adverse effects
  • Heart Valve Prosthesis Implantation / instrumentation*
  • Heart Valve Prosthesis Implantation / mortality
  • Heart Valve Prosthesis*
  • Humans
  • Male
  • Operative Time
  • Postoperative Complications / mortality
  • Postoperative Complications / therapy
  • Prospective Studies
  • Prosthesis Design
  • Reoperation
  • Severity of Illness Index
  • Sutureless Surgical Procedures* / adverse effects
  • Sutureless Surgical Procedures* / mortality
  • Time Factors
  • Treatment Outcome