The role of cardiac testing with the 0/1-hour high-sensitivity cardiac troponin algorithm evaluating for acute myocardial infarction

Am Heart J. 2021 Mar:233:68-77. doi: 10.1016/j.ahj.2020.12.015. Epub 2020 Dec 26.

Abstract

Background: The role of cardiac testing in the 3 zones (rule-out, observation, and rule-in) of the 0/1-hour algorithm to evaluate for acute myocardial infarction (AMI) has not been well studied. This study evaluated the 0/1-hour algorithm with a high-sensitivity cardiac troponin (hs-cTnI) assay and investigated cardiac testing in the 3 zones.

Methods: Patients (n = 552) at a single urban center were enrolled if they were evaluated for AMI. Blood samples were obtained at presentation, 1 hour, and 3 hours for hs-cTnI. Follow-up at 30 to 45 days for death/AMI was done. The results of echocardiograms, stress testing, and coronary angiography were recorded.

Results: In total, 45 (8.2%) had AMI (27 Type 1 and 18 Type 2) during the index hospitalization while at follow-up death/AMI occurred in 11 (2.0%) of patients. The rule-out algorithm had a negative predictive value for AMI of 99.6% while the rule-in zone had a positive predictive value of 56.6%. The MACE rate at follow-up was 0.4% for those in the rule-out group. There were 6/95 (6.3%) abnormal stress tests in the rule-out zone and 4 of these were false positives.

Conclusions: The 0/1-hour algorithm had high diagnostic sensitivity and negative predictive value for AMI, and adverse events were very low in patients in the rule-out zone. Noninvasive testing in rule-out zone patients had low diagnostic yield.

Publication types

  • Research Support, Non-U.S. Gov't
  • Validation Study

MeSH terms

  • Algorithms*
  • Biomarkers / blood
  • Coronary Angiography
  • Echocardiography
  • Exercise Test
  • Female
  • Humans
  • Male
  • Middle Aged
  • Myocardial Infarction / diagnosis*
  • Myocardial Infarction / mortality
  • Predictive Value of Tests
  • Time Factors
  • Troponin I / blood*

Substances

  • Biomarkers
  • Troponin I