Ventricular arrhythmia burden during the coronavirus disease 2019 (COVID-19) pandemic

Eur Heart J. 2021 Feb 1;42(5):520-528. doi: 10.1093/eurheartj/ehaa893.

Abstract

Aims: Our objective was to determine the ventricular arrhythmia burden in implantable cardioverter-defibrillator (ICD) patients during COVID-19.

Methods and results: In this multicentre, observational, cohort study over a 100-day period during the COVID-19 pandemic in the USA, we assessed ventricular arrhythmias in ICD patients from 20 centres in 13 states, via remote monitoring. Comparison was via a 100-day control period (late 2019) and seasonal control period (early 2019). The primary outcome was the impact of COVID-19 on ventricular arrhythmia burden. The secondary outcome was correlation with COVID-19 incidence. During the COVID-19 period, 5963 ICD patients underwent remote monitoring, with 16 942 episodes of treated ventricular arrhythmias (2.8 events per 100 patient-days). Ventricular arrhythmia burden progressively declined during COVID-19 (P < 0.001). The proportion of patients with ventricular arrhythmias amongst the high COVID-19 incidence states was significantly reduced compared with those in low incidence states [odds ratio 0.61, 95% confidence interval (CI) 0.54-0.69, P < 0.001]. Comparing patients remotely monitored during both COVID-19 and control periods (n = 2458), significantly fewer ventricular arrhythmias occurred during COVID-19 [incident rate ratio (IRR) 0.68, 95% CI 0.58-0.79, P < 0.001]. This difference persisted when comparing the 1719 patients monitored during both the COVID-19 and seasonal control periods (IRR 0.69, 95% CI 0.56-0.85, P < 0.001).

Conclusions: During COVID-19, there was a 32% reduction in ventricular arrhythmias needing device therapies, coinciding with measures of social isolation. There was a 39% reduction in the proportion of patients with ventricular arrhythmias in states with higher COVID-19 incidence. These findings highlight the potential role of real-life stressors in ventricular arrhythmia burden in individuals with ICDs.

Trial registration: Australian New Zealand Clinical Trial Registry; URL: https://www.anzctr.org.au/; Unique Identifier: ACTRN12620000641998.

Keywords: COVID-19; Implantable cardioverter-defibrillator; Remote monitoring; Ventricular arrhythmia; Ventricular fibrillation; Ventricular tachycardia.

Publication types

  • Multicenter Study
  • Observational Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Arrhythmias, Cardiac / epidemiology*
  • Arrhythmias, Cardiac / etiology
  • Arrhythmias, Cardiac / therapy
  • COVID-19* / epidemiology
  • COVID-19* / prevention & control
  • Cost of Illness
  • Defibrillators, Implantable*
  • Female
  • Humans
  • Incidence
  • Logistic Models
  • Male
  • Middle Aged
  • Monitoring, Physiologic
  • Pandemics
  • Physical Distancing
  • Protective Factors
  • Registries
  • Risk Factors
  • Stress, Psychological
  • Telemedicine
  • United States / epidemiology
  • Ventricular Fibrillation / epidemiology*
  • Ventricular Fibrillation / etiology
  • Ventricular Fibrillation / therapy