Abstract

Aims: Our aim was to analyse whether using delayed enhancement cardiac magnetic resonance imaging (DE-CMR) to localize veno-atrial gaps in atrial fibrillation (AF) redo ablation procedures improves outcomes during follow-up.

Methods and results: We conducted a case-control study with 35 consecutive patients undergoing a DE-CMR-guided Repeat-pulmonary vein isolation (Re-PVI) procedure. Those with more extensive ablations (e.g. roof lines, box) were excluded. Patients were matched for age, sex, AF pattern, and left atrial dimension with 35 patients who had undergone a conventional Re-PVI procedure guided with a three dimensional (3D)-navigation system. Procedural characteristics were recorded, and patients were followed for 24 months in a specialized outpatient clinic. The primary endpoint was freedom from recurrent AF, atrial tachycardia, or flutter. The duration of CMR-guided procedures was shorter compared to the conventional group (161 ± 52 vs. 195 ± 72 min, respectively, P = 0.049), with no significant differences in fluoroscopy or total radiofrequency time. At the 2-year follow-up, more patients in the DE-CMR-guided group remained free from recurrences compared with the conventional group (70% vs. 39%, respectively, P = 0.007). In univariate Cox-regression analyses, AF pattern [persistent AF, hazard ratio (HR) 2.66 (1.27-5.46), P = 0.006] and the use of DE-CMR [HR 0.36 (0.17-0.79), P = 0.009] predicted recurrences during follow-up; both factors remained independent predictors in multivariate analyses.

Conclusion: The substrate characterization provided by DE-CMR facilitates the identification of anatomical veno-atrial gaps and associates with shorter procedures and better clinical outcomes in repeated AF ablation procedures.

Keywords: Atrial fibrillation; Atrial fibrosis; Delayed enhancement cardiac magnetic resonance-guided atrial fibrillation ablation; Pulmonary vein reconnection.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Atrial Fibrillation* / diagnostic imaging
  • Atrial Fibrillation* / surgery
  • Case-Control Studies
  • Catheter Ablation* / adverse effects
  • Humans
  • Magnetic Resonance Spectroscopy
  • Pulmonary Veins* / diagnostic imaging
  • Pulmonary Veins* / surgery
  • Recurrence
  • Treatment Outcome