High-intensity interval training in patients with left ventricular assist devices: A pilot randomized controlled trial

J Heart Lung Transplant. 2020 Dec;39(12):1380-1388. doi: 10.1016/j.healun.2020.08.005. Epub 2020 Aug 20.

Abstract

Background: Left ventricular assist device (LVAD) implantation is an established treatment for patients with advanced heart failure. To date, studies evaluating the impact of aerobic training in patients with LVADs have focused on moderate-intensity exercise.

Methods: This pilot randomized controlled trial compared the effects of high-intensity interval training (HIIT) with those of moderate-intensity continuous training (MICT) on peak oxygen consumption (V̇O2 peak) in patients with LVADs. Secondary outcomes included 6-minute walk test distance, flow-mediated dilation, and anthropometry. Assessments were conducted at baseline and after 12 weeks of supervised training performed 3 times weekly. Participants were randomized to HIIT (4 sets of 4 minutes at 80%-90% V̇O2 reserve, alternating with 3 minutes at 50%-60% V̇O2 reserve) or MICT groups (28 minutes continuously at 50%-60% V̇O2 reserve). Within and between-group differences were analyzed using linear mixed models. Data are expressed as marginal means with 95% confidence intervals or as mean ± SD.

Results: A total of 21 participants were randomized (HIIT: age 57.7 ± 13.1 years; n = 11 and MICT: age 55.6 ± 14.2 years; n = 10) (mean ± SD). No major adverse events occurred in response to training in either group. HIIT significantly improved V̇O2 peak (15.6 [13.2-17.8] to 18.4 [16.0-20.8] ml/kg/min) (marginal mean [95% CI]) compared with MICT (16.2 [13.8-18.7] to 17.2 [14.6-19.7] ml/kg/min; p < 0.05 between groups). No significant group differences were detected in secondary outcomes.

Conclusion: In patients with LVADs, HIIT was well tolerated and increased aerobic capacity more than MICT. These preliminary findings support the prescription of high-intensity exercise in clinically stable patients with LVADs but warrant validation in a larger sample and across a broader range of physiologic and clinical outcomes.

Clinical trial registration: URL: https://www.anzctr.org.au, unique identifier: ACTRN12616001596493.

Keywords: aerobic capacity; anthropometry; endothelial function; exercise training; high intensity; left ventricular assist device; six minute walk test.

Publication types

  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Exercise / physiology*
  • Exercise Therapy / methods*
  • Female
  • Follow-Up Studies
  • Heart Failure / physiopathology
  • Heart Failure / rehabilitation*
  • Heart Rate / physiology*
  • Heart Ventricles / physiopathology*
  • High-Intensity Interval Training / methods*
  • Humans
  • Male
  • Middle Aged
  • Oxygen Consumption / physiology
  • Pilot Projects
  • Prospective Studies
  • Treatment Outcome
  • Ventricular Function, Left / physiology*

Associated data

  • ANZCTR/ACTRN12616001596493