One-Year Echocardiographic, Functional, and Quality of Life Outcomes After Ultrasound-Facilitated Catheter-Based Fibrinolysis for Pulmonary Embolism

Circ Cardiovasc Interv. 2020 Aug;13(8):e009012. doi: 10.1161/CIRCINTERVENTIONS.120.009012. Epub 2020 Aug 6.

Abstract

Background: Accelerated tPA (tissue-type plasminogen activator) dosing regimens for ultrasound-facilitated, catheter-directed fibrinolysis improve short-term computed tomographic-measured right ventricular (RV)-to-left ventricular diameter ratio in massive and submassive pulmonary embolism. The impact on RV remodeling, functional status, and quality of life over the long-term remains unclear.

Methods: To study 1-year changes in RV remodeling, functional status, and quality of life, we assessed patients with acute submassive pulmonary embolism randomly assigned to 1 of 4 tPA dosing regimens for ultrasound-facilitated, catheter-directed fibrinolysis in the OPTALYSE-PE trial (Optimum Duration and Dose of r-tPA With the Acoustic Pulse Thrombolysis Procedure for Intermediate-Risk Pulmonary Embolism; 8 mg/2 hours, 8 mg/4 hours, 12 mg/6 hours, and 24 mg/6 hours). Echocardiographic assessment included RV-to-left ventricular diameter ratio within 4 hours of treatment end, and at 48 hours, 30 days, 90 days, and 1 year. Functional status was assessed by 6-minute walk test at 30 days, 90 days, and 1 year and PROMIS-PF-6b scores at 30 days, 90 days, 180 days, 270 days, and 1 year. Quality of life was evaluated by PEmb-QOL scores at 30 days, 90 days, 180 days, 270 days, and 1 year.

Results: Mean RV-to-left ventricular diameter ratio decreased from baseline to 4 hours and further at 48 hours and 30 days, with reductions maintained at 90 days and 1 year in all groups. Mean 6-minute walk distance, PROMIS-PF-6b, and PEmb-QOL scores improved over the course of 1 year in all groups.

Conclusions: Accelerated lower-dose tPA regimens for ultrasound-facilitated, catheter-directed fibrinolysis resulted in sustained recovery of RV-to-left ventricular diameter ratio and tricuspid annular plane systolic excursion and improvements in functional status and quality of life over 1 year. Registration: URL: https://www.ClinicalTrials.gov. Unique Identifier: NCT02396758.

Keywords: echocardiography; fibrinolysis; pulmonary artery; pulmonary embolism; quality of life.

Publication types

  • Comparative Study
  • Multicenter Study
  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Echocardiography*
  • Europe
  • Exercise Tolerance
  • Female
  • Fibrinolytic Agents / administration & dosage*
  • Fibrinolytic Agents / adverse effects
  • Functional Status
  • Humans
  • Male
  • Middle Aged
  • Predictive Value of Tests
  • Pulmonary Embolism / diagnostic imaging
  • Pulmonary Embolism / drug therapy*
  • Pulmonary Embolism / physiopathology
  • Quality of Life*
  • Recovery of Function
  • Thrombolytic Therapy* / adverse effects
  • Time Factors
  • Tissue Plasminogen Activator / administration & dosage*
  • Tissue Plasminogen Activator / adverse effects
  • Treatment Outcome
  • Ultrasonography, Interventional*
  • United States
  • Ventricular Function, Right*
  • Ventricular Remodeling*
  • Young Adult

Substances

  • Fibrinolytic Agents
  • Tissue Plasminogen Activator

Associated data

  • ClinicalTrials.gov/NCT02396758