The relation between cardiac 123I-mIBG scintigraphy and functional response 1 year after CRT implantation

Eur Heart J Cardiovasc Imaging. 2021 Jan 1;22(1):49-57. doi: 10.1093/ehjci/jeaa045.

Abstract

Aims: Cardiac resynchronization therapy (CRT) is a disease-modifying therapy in patients with chronic heart failure (CHF). Current guidelines ascribe CRT eligibility on three parameters only: left ventricular ejection fraction (LVEF), QRS duration, and New York Heart Association (NYHA) functional class. However, one-third of CHF patients does not benefit from CRT. This study evaluated whether 123I-meta-iodobenzylguanidine (123I-mIBG) assessed cardiac sympathetic activity could optimize CRT patient selection.

Methods and results: A total of 78 stable CHF subjects (age 66.8 ± 9.6 years, 73% male, LVEF 25.2 ± 6.7%, QRS duration 153 ± 23 ms, NYHA 2.2 ± 0.7) referred for CRT implantation were enrolled. Subjects underwent 123I-mIBG scintigraphy prior to implantation. Early and late heart-to-mediastinum (H/M) ratio and 123I-mIBG washout were calculated. CRT response was defined as either an increase of LVEF to >35%, any improvement in LVEF of >10%, QRS shortening to <150 ms, or improvement in NYHA class of >1 class. In 33 patients LVEF increased to >35%, QRS decreased <150 ms in 36 patients, and NYHA class decreased in 33 patients. Late H/M ratio and hypertension were independent predictors of LVEF improvement to >35% (P = 0.0014 and P = 0.0149, respectively). In addition, early H/M ratio, LVEF, and absence of diabetes mellitus (DM) were independent predictors for LVEF improvement by >10%. No independent predictors were found for QRS shortening to <150 ms or improvement in NYHA class.

Conclusion: Early and late H/M ratio were independent predictors of CRT response when improvement of LVEF was used as measure of response. Therefore, cardiac 123I-mIBG scintigraphy may be used as a tool to optimize selection of subjects that might benefit from CRT.

Keywords: 123I-mIBG scintigraphy; cardiac resynchronization therapy; chronic heart failure; heart-to-mediastinum ratio; response; wash out.

MeSH terms

  • 3-Iodobenzylguanidine
  • Aged
  • Cardiac Resynchronization Therapy*
  • Female
  • Heart Failure* / diagnostic imaging
  • Heart Failure* / therapy
  • Humans
  • Iodine Radioisotopes
  • Male
  • Middle Aged
  • Radionuclide Imaging
  • Radiopharmaceuticals
  • Stroke Volume
  • Ventricular Function, Left

Substances

  • Iodine Radioisotopes
  • Radiopharmaceuticals
  • 3-Iodobenzylguanidine
  • Iodine-123