Objective

To describe percutaneous left atrial appendage closure (LAAc) in a patient with recurrent gastric ulcer bleeding with the help of the TrueFusion™ fusion-imaging system.

Method and results

In a patient with paroxysmal atrial fibrillation, the need for an effective oral anticoagulation and recurrent gastrointestinal bleeding, left atrial appendage closure (LAAc) was performed under guidance of the TrueFusion™ fusion-imaging technology (Siemens Healthineers, Erlangen, Germany) to enhance procedural precision, save radiation time and contrast dye. Left atrial appendage closure was performed with the use of a 20 mm Amplatzer Amulet™ (Abbott Laboratories, Chicago, IL, USA) using the TrueFusion™ system under mild sedation with minimal use of contrast. Intraprocedural transesophageal echocardiography revealed complete LAA occlusion without residual flow. The patient was uneventfully discharged on the second postoperative day.

Conclusion

LAAc using an integrated approach combining ultrasound and live fluoroscopy, as provided by the TrueFusion™, is safe and feasible. Target-oriented device navigation and synchronized image orientation as provided by fusion imaging may potentially be beneficial regarding radiation time, contrast dye and periprocedural risk of suboptimal device positioning.

Graphic abstract

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

References

  1. Blackshear JL, Odell JA (1996) Appendage obliteration to reduce stroke in cardiac surgical patients with atrial fibrillation. Ann Thorac Surg 61:755–759

    Article  CAS  Google Scholar 

  2. Klein AL, Grimm RA, Murray RD, -Hansen C, Asinger RW, Black IW, Davidoff R, Erbel R, Halperin JL, Orsinelli DA, Porter TR, Stoddard MF (2001) Use of transesophageal echocardiography to guide cardioversion in patients with atrial fibrillation. N Engl J Med 344:1411–1420

    Article  CAS  Google Scholar 

  3. Onalan O, Crystal E (2007) Left atrial appendage exclusion for stroke prevention in patients with nonrheumatic atrial fibrillation. Stroke 38:624–630

    Article  Google Scholar 

  4. Sedaghat A, Vij V, Streit SR, Schrickel JW, Al-Kassou B, Nelles D, Kleinecke C, Windecker S, Meier B, Valglimigli M, Nietlispach F, Nickenig G, Gloekler S (2019) Incidence, predictors, and relevance of acute kidney injury in patients undergoing left atrial appendage closure with Amplatzer occluders: a multicentre observational study. Clin Res Cardiol. https://doi.org/10.1007/s00392-019-01524-9

    Article  PubMed  Google Scholar 

  5. Fink T, Schluter M, Tilz RR, Heeger CH, Lemes C, Maurer T, Reissmann B, Rottner L, Santoro F, Mathew S, Rillig A, Ouyang F, Kuck KH, Metzner A (2018) Acute and long-term outcomes of epicardial left atrial appendage ligation with the second-generation LARIAT device: a high-volume electrophysiology center experience. Clin Res Cardiol 107:1139–1147

    Article  CAS  Google Scholar 

  6. Hell MM, Achenbach S, Yoo IS, Franke J, Blachutzik F, Roether J, Graf V, Raaz-Schrauder D, Marwan M, Schlundt C (2017) 3D printing for sizing left atrial appendage closure device: head-to-head comparison with computed tomography and transoesophageal echocardiography. EuroIntervention 13:1234–1241

    Article  Google Scholar 

  7. Rajwani A, Nelson AJ, Shirazi MG, Disney PJS, Teo KSL, Wong DTL, Young GD, Worthley SG (2017) CT sizing for left atrial appendage closure is associated with favourable outcomes for procedural safety. Eur Heart J Cardiovasc Imaging 18:1361–1368

    Article  Google Scholar 

  8. Ternacle J, Lellouche N, Deux JF, Rande JL, Teiger E, Lim P (2014) Left atrial appendage closure monitoring without sedation: a pilot study using intracardiac echocardiography through the oesophageal route. EuroIntervention 11:936–941

    Article  Google Scholar 

  9. Yazdani KO, Mitomo S, Ruparelia N, Candilio L, Giannini F, Jabbour RJ, Regazzoli D, Mazzone P, Stella S, Sora N, Montorfano M, Colombo A, Latib A (2019) Percutaneous left atrial appendage occlusion with the Amulet device: the impact of device disc position upon periprocedural and long-term outcomes. Catheter Cardiovasc Interv 93:120–127

    Article  Google Scholar 

  10. Aminian A, Lempereur M, Yedder MB, Dubois P (2018) Real-time fusion of echocardiography and fluoroscopy allowing successful implantation of a WATCHMAN device without contrast injection. EuroIntervention. 14:174–175

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Alexander Sedaghat.

Ethics declarations

Conflict of interest

There are no conflicts of interest.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Nelles, D., Schrickel, J.W., Nickenig, G. et al. Percutaneous left atrial appendage closure using the TrueFusion™ fusion-imaging technology. Clin Res Cardiol 109, 646–648 (2020). https://doi.org/10.1007/s00392-019-01566-z

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00392-019-01566-z

Keywords

Navigation