Prosthesis-Patient Mismatch Following Transcatheter Aortic Valve Replacement With Supra-Annular and Intra-Annular Prostheses

JACC Cardiovasc Interv. 2019 Nov 11;12(21):2173-2182. doi: 10.1016/j.jcin.2019.07.027. Epub 2019 Sep 26.

Abstract

Objectives: This study sought to compare the frequency of prosthesis-patient mismatch (PPM) with self-expandable valves (SEV) to balloon-expandable valves (BEV).

Background: PPM has been associated with increased mortality after transcatheter aortic valve replacement. Data on the frequency of PPM as a function of supra-annular or intra-annular position of transcatheter heart valves are insufficient.

Methods: A total of 757 patients treated with SEV (CoreValve, Evolut R) and BEV (SAPIEN THV/XT/3) were enrolled in the present analysis between August 2007 and June 2017. PPM was classified based on discharge prosthetic effective orifice area indexed to body surface area (BSA) as severe (<0.65 cm2/m2) or moderate (0.65 to 0.85 cm2/m2) in the general population, and as severe (<0.60 cm2/m2) or moderate (0.60 to 0.90 cm2/m2) in the obese population (body mass index ≥30 kg/m2).

Results: Propensity score matching resulted in 224 matched pairs. At discharge, SEV were associated with a lower incidence of PPM compared with BEV (PPM, 33.5% vs. 46.9%; p = 0.004; severe PPM, 6.7% vs. 15.6%; p = 0.003). The lower frequency of severe PPM in SEV was observed even in patients with larger annulus. Although patients with BSA >1.83 m2 had a significantly lower incidence of PPM with SEV compared with BEV, there was no significant difference in patients with BSA ≤1.83 m2. We found no impact of PPM on cardiovascular mortality or New York Heart Association functional class at 1 year.

Conclusions: SEV were associated with a lower frequency of PPM compared with BEV irrespective of annulus area. The difference was mainly driven by larger patients with BSA >1.83 m2.

Keywords: aortic stenosis; intra-annular valve; prosthesis-patient mismatch; supra-annular valve; transcatheter aortic valve replacement.

Publication types

  • Comparative Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Valve / diagnostic imaging
  • Aortic Valve / physiopathology
  • Aortic Valve / surgery*
  • Balloon Valvuloplasty* / adverse effects
  • Female
  • Heart Valve Diseases / diagnostic imaging
  • Heart Valve Diseases / physiopathology
  • Heart Valve Diseases / surgery*
  • Heart Valve Prosthesis*
  • Hemodynamics
  • Humans
  • Male
  • Prosthesis Design
  • Recovery of Function
  • Registries
  • Risk Assessment
  • Risk Factors
  • Switzerland
  • Time Factors
  • Transcatheter Aortic Valve Replacement / adverse effects
  • Transcatheter Aortic Valve Replacement / instrumentation*
  • Treatment Outcome