Diagnostic Accuracy of FDG PET/CT in Suspected LVAD Infections: A Case Series, Systematic Review, and Meta-Analysis

JACC Cardiovasc Imaging. 2020 May;13(5):1191-1202. doi: 10.1016/j.jcmg.2019.04.024. Epub 2019 Jul 17.

Abstract

Objectives: The purpose of this study was to describe our experience with fluorine-18 fluorodeoxyglucose (FDG) positron emission tomography computed tomography (PET/CT) in diagnosing left ventricular assist device (LVAD) infections and perform a meta-analysis of published studies to determine overall diagnostic accuracy.

Background: Device-related infections are a common complication of LVADs and are linked to worse outcomes. Diagnosis of LVAD infections remains challenging. FDG PET/CT has demonstrated good diagnostic accuracy in several other infectious conditions.

Methods: This was a single-center, retrospective case series of FDG PET/CT scans in suspected LVAD infection between September 2015 and February 2018. A systematic review of PubMed from database inception through March 2018 was also conducted to identify additional studies.

Results: Nineteen FDG PET/CT scans were identified for the retrospective case series. The systematic review identified an additional 3 publications, for a total of 4 studies involving 119 scans assessing diagnostic performance. Axial (n = 36) and centrifugal (n = 83) flow LVADs were represented. Pooled sensitivity was 92% (95% confidence interval [CI]: 82% to 97%) and specificity was 83% (95% CI: 24% to 99%) for FDG PET/CT in diagnosing LVAD infections. Summary receiver-operating characteristic curve analysis demonstrated an AUC of 0.94 (95% CI: 0.91 to 0.95).

Conclusions: FDG PET/CT for suspected LVAD infections demonstrates good diagnostic accuracy, with overall high sensitivity but variable specificity.

Keywords: diagnostic testing; heart failure; infection; left ventricular assist device; meta-analysis; positron emission tomography.

Publication types

  • Meta-Analysis
  • Research Support, N.I.H., Extramural
  • Systematic Review

MeSH terms

  • Aged
  • Female
  • Fluorodeoxyglucose F18 / administration & dosage*
  • Heart-Assist Devices / adverse effects*
  • Humans
  • Male
  • Middle Aged
  • Positron Emission Tomography Computed Tomography*
  • Predictive Value of Tests
  • Prosthesis-Related Infections / diagnostic imaging*
  • Prosthesis-Related Infections / microbiology
  • Radiopharmaceuticals / administration & dosage*
  • Reproducibility of Results
  • Retrospective Studies

Substances

  • Radiopharmaceuticals
  • Fluorodeoxyglucose F18