RAPID-CPU: a prospective study on implementation of the ESC 0/1-hour algorithm and safety of discharge after rule-out of myocardial infarction

Eur Heart J Acute Cardiovasc Care. 2020 Feb;9(1):39-51. doi: 10.1177/2048872619861911. Epub 2019 Jul 12.

Abstract

Background: Although the value of fast diagnostic protocols in suspected acute coronary syndrome has been validated, there is insufficient real world evidence including patients with lower pre-test probability, atypical symptoms and confounding comorbidities. The feasibility, efficacy and safety of European Society of Cardiology (ESC) 0/1 and 0/3-hour algorithms using high-sensitivity troponin T were evaluated in a consecutive cohort with suspected acute coronary syndrome.

Methods: During 12 months, 2525 eligible patients were enrolled. In a pre-implementation period of 6 months, the prevalence of protocols, disposition, lengths of emergency department stay and treatments were registered. Implementation of the 0/1-hour protocol was monitored for another 6 months. Primary endpoints comprised the change of diagnostic protocols and 30-day mortality after direct discharge from the emergency department.

Results: Use of the ESC 0/1-hour algorithm increased by 270% at the cost of the standard 0/3-hour protocol. After rule-out (1588 patients), 1309 patients (76.1%) were discharged directly from the emergency department, with an all-cause mortality of 0.08% at 30 days (one death due to lung cancer). Median lengths of stay were 2.9 (1.9-3.8) and 3.2 (2.7-4.4) hours using a single high-sensitivity troponin T below the limit of detection (5 ng/L) at presentation and the ESC 0/1-hour algorithm, respectively, as compared to 5.3 (4.7-6.5) hours using the ESC 0/3-hour rule-out protocol (P<0.001). Discharge rates increased from 53.9% to 62.8% (P<0.001), without excessive use of diagnostic resources within 30 days.

Conclusion: Implementation of the ESC 0/1-hour algorithm is feasible and safe, is associated with shorter emergency department stay than the ESC 0/3-hour protocol, and an increase in discharge rates.

Trial registration: ClinicalTrials.gov , Unique identifier: NCT03111862.

Keywords: Acute coronary syndrome; clinical protocols; high-sensitivity troponin; real world evidence.

MeSH terms

  • Acute Coronary Syndrome / blood
  • Acute Coronary Syndrome / diagnosis*
  • Acute Coronary Syndrome / physiopathology
  • Adult
  • Aged
  • Aged, 80 and over
  • Algorithms
  • Cardiology / organization & administration
  • Clinical Protocols / standards
  • Comorbidity
  • Efficiency, Organizational
  • Emergency Service, Hospital / statistics & numerical data
  • Europe / epidemiology
  • Feasibility Studies
  • Female
  • Humans
  • Length of Stay / statistics & numerical data
  • Male
  • Middle Aged
  • Myocardial Infarction / blood
  • Myocardial Infarction / diagnosis*
  • Myocardial Infarction / mortality
  • Patient Discharge / statistics & numerical data*
  • Patient Discharge / trends
  • Prevalence
  • Prospective Studies
  • Safety
  • Societies, Medical
  • Time Factors
  • Troponin T / blood*

Substances

  • Troponin T

Associated data

  • ClinicalTrials.gov/NCT03111862