Cluster Randomized Trial Examining the Impact of Automated Best Practice Alert on Rates of Implantable Defibrillator Therapy

Circ Cardiovasc Qual Outcomes. 2019 Jun;12(6):e005024. doi: 10.1161/CIRCOUTCOMES.118.005024. Epub 2019 Jun 11.

Abstract

Background Implantable cardioverter-defibrillators (ICDs) are indicated in patients with left ventricular ejection fraction ≤35%, but many eligible patients do not receive this therapy. In this cluster randomized trial, we investigated the impact of a best practice alert (BPA) through the electronic health records on the rates of electrophysiology referrals, ICD implantations, and all-cause mortality in severe cardiomyopathy patients. Methods and Results Providers in the Heart and Vascular Institute (n=106) and in General Internal Medicine (n=89) were randomized to receive or not receive a BPA recommending consideration for ICD implantation. Patients belonging to the BPA and no BPA groups of providers were followed to the end points of electrophysiology referrals, ICD implantations, and all-cause mortality. Between 2013 and 2015, patients with reduced left ventricular ejection fraction were managed by 93 providers in the BPA (n=997 patients) and 102 providers in the no BPA (n=909 patients) groups. Patients in the 2 groups had comparable baseline characteristics. After a median follow-up of 36 months, 638 (33%) patients were referred to electrophysiology, 536 (27%) received an ICD, and 445 (23%) died. Patients in the BPA group were more likely to be referred to electrophysiology (hazard ratio=1.23; P=0.026), to receive ICD therapy (hazard ratio=1.35; P=0.006), and exhibited a trend towards slightly lower mortality (hazard ratio=0.85; P=0.091). Conclusions Delivering a BPA through the electronic health record recommending to providers consideration of ICD implantation when the left ventricular ejection fraction is ≤35% improves the rates of electrophysiology referrals and ICD therapy in patients with severe left ventricular dysfunction.

Keywords: electrophysiology; heart failure; mortality; primary prevention; ventricular dysfunction.

Publication types

  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Cardiomyopathies / diagnostic imaging
  • Cardiomyopathies / mortality
  • Cardiomyopathies / physiopathology
  • Cardiomyopathies / therapy*
  • Cause of Death
  • Death, Sudden, Cardiac / prevention & control*
  • Defibrillators, Implantable*
  • Electric Countershock / instrumentation*
  • Electronic Health Records*
  • Female
  • Humans
  • Male
  • Middle Aged
  • Pennsylvania
  • Prospective Studies
  • Referral and Consultation
  • Reminder Systems*
  • Risk Assessment
  • Risk Factors
  • Stroke Volume*
  • Treatment Outcome
  • Ventricular Dysfunction, Left / diagnosis
  • Ventricular Dysfunction, Left / mortality
  • Ventricular Dysfunction, Left / physiopathology
  • Ventricular Dysfunction, Left / therapy*
  • Ventricular Function, Left*
  • Young Adult