Implantable cardioverter defibrillators in arrhythmogenic right ventricular dysplasia/cardiomyopathy: patient outcomes, incidence of appropriate and inappropriate interventions, and complications

Circ Arrhythm Electrophysiol. 2013 Jun;6(3):562-8. doi: 10.1161/CIRCEP.113.000392. Epub 2013 May 14.

Abstract

Background: Arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVD/C) is a cardiomyopathy characterized by ventricular arrhythmias and an abnormal right ventricle. Implantable cardioverter defibrillator (ICD) therapy may prevent sudden cardiac death in patients with ARVD/C. Currently, an overview of outcomes, appropriate and inappropriate interventions, and complications of ICD therapy in ARVD/C is lacking.

Methods and results: A literature search was performed to identify studies reporting outcome and complications in patients with ARVD/C who underwent ICD implantation. Of 641 articles screened, 24 studies on 18 cohorts were eligible for inclusion. In case of multiple publications on a cohort, the most recent publication was included in the meta-analysis. There were 610 patients (mean age, 40.4 years; 42% women), who had an ICD for primary or secondary prevention of sudden cardiac death. Risk factors for sudden cardiac death were presyncope (61%), syncope (31%), previous cardiac arrest (14%), ventricular tachycardia (58%), and ventricular fibrillation (6%). Antiarrhythmic medication consisted mostly of β-blockers (38%), amiodarone (14%), or sotalol (30%). During the 3.8-year follow-up, annualized cardiac mortality rate was 0.9%, annualized noncardiac mortality rate was 0.8%, and annualized heart transplant rate was 0.9%. The annualized appropriate and inappropriate ICD intervention rates were 9.5% and 3.7%, respectively. ICD-related complications consisted of difficult lead placement (18.4%), lead malfunction (9.8%), infection (1.4%), lead displacement (3.3%), and any complication (20.3%).

Conclusions: Cardiac and noncardiac mortality rates after ICD implantation in patients with ARVD/C are low. Appropriate ICD interventions occur at a rate of 9.5%/y. Inappropriate ICD interventions and complications lead to considerable ICD-related morbidity.

Keywords: arrhythmogenic right ventricular dysplasia/cardiomyopathy; complication; implantable cardioverter defibrillator; prognosis; sudden cardiac death.

Publication types

  • Comparative Study
  • Meta-Analysis
  • Review

MeSH terms

  • Adult
  • Aged
  • Anti-Arrhythmia Agents / therapeutic use
  • Arrhythmogenic Right Ventricular Dysplasia / diagnosis*
  • Arrhythmogenic Right Ventricular Dysplasia / mortality
  • Arrhythmogenic Right Ventricular Dysplasia / therapy*
  • Death, Sudden, Cardiac*
  • Defibrillators, Implantable*
  • Female
  • Humans
  • Male
  • Middle Aged
  • Prognosis
  • Risk Assessment
  • Survival Rate
  • Tachycardia, Ventricular / diagnosis
  • Tachycardia, Ventricular / drug therapy
  • Tachycardia, Ventricular / mortality
  • Treatment Outcome
  • Ventricular Fibrillation / diagnosis
  • Ventricular Fibrillation / drug therapy
  • Ventricular Fibrillation / mortality

Substances

  • Anti-Arrhythmia Agents