Contemporary treatment of mitral valve disease with transcatheter mitral valve implantation

Clin Res Cardiol. 2023 May;112(5):571-584. doi: 10.1007/s00392-022-02095-y. Epub 2022 Sep 15.

Abstract

Background: Transcatheter mitral valve implantation (TMVI) with self-expanding (SAV) or balloon-expandable (BAV) valves are rising as promising treatment options for high-risk patients with symptomatic mitral valve (MVD) disease unsuitable for alternative treatment options.

Aims: The aim of this study was to examine the clinical, procedural and outcome parameters of patients undergoing SAV or BAV for MVD.

Methods: In this observational and single-center case series, fifteen consecutive patients treated with the Tendyne Mitral Valve System (SAV) and thirty-one patients treated with SAPIEN prosthesis (BAV) were included.

Results: The patients (aged 78 years [interquartile range (IQR): 65.5 to 83.1 years], 41% women, EuroSCORE II 10.3% [IQR: 5.5 to 17.0%] were similar regarding baseline characteristics, despite a higher rate of prior heart valve surgery and prevalence of MV stenosis in the SAV-group. At discharge, the SAV-group had a mean transvalvular gradient of 4.2 mmHg, whereas the BAV-group had a mean transvalvular gradient of 6.2 mmHg. None or trace paravalvular leakage (PVL) was assessed in 85% in SAV-group and 80% in the BAV-group. 320 day all-cause and cardiac mortality rates were comparable in both groups (SAV: 26.7% vs BAV: 20%, p = 0.60). Four deaths occurred early in the SAV-group until 32 days of follow-up.

Conclusions: In high-risk patients with MVD, TMVI presents a promising treatment option with encouraging mid-term outcomes and good valve durability. TMVI either with BAV or SAV may be developed to an established treatment option.

Keywords: Heart valve prosthesis; Mitral valve disease; Tendyne; Transcatheter mitral valve implantation; Valve-in-valve.

MeSH terms

  • Aortic Valve / surgery
  • Aortic Valve Stenosis* / surgery
  • Female
  • Heart Valve Diseases* / surgery
  • Heart Valve Prosthesis Implantation* / adverse effects
  • Heart Valve Prosthesis*
  • Humans
  • Male
  • Mitral Valve / diagnostic imaging
  • Mitral Valve / surgery
  • Prosthesis Design
  • Transcatheter Aortic Valve Replacement*
  • Treatment Outcome