An unexpected circular shunt: Novel method to treat semilunar valve insufficiency in a single ventricle patient on mechanical circulatory support

Catheter Cardiovasc Interv. 2022 Sep;100(3):395-398. doi: 10.1002/ccd.30343. Epub 2022 Jul 28.

Abstract

Severe semilunar valve insufficiency in single ventricle patients supported with mechanical circulatory support while awaiting transplant remains a complex clinical scenario with few favorable options for management. We present the first case, to our knowledge, of transcatheter closure of the pulmonic valve in a patient palliated with a hybrid stage 1 procedure for hypoplastic left heart syndrome.

Keywords: interventional devices/innovation; mechanical circulatory support; percutaneous intervention; pulmonary valve disease; ventricular assist device.

Publication types

  • Case Reports

MeSH terms

  • Aortic Valve
  • Aortic Valve Insufficiency* / diagnostic imaging
  • Aortic Valve Insufficiency* / etiology
  • Aortic Valve Insufficiency* / surgery
  • Heart-Assist Devices*
  • Humans
  • Hypoplastic Left Heart Syndrome* / diagnostic imaging
  • Hypoplastic Left Heart Syndrome* / surgery
  • Treatment Outcome