Differences in Prognostic Value of Myocardial Perfusion Single-Photon Emission Computed Tomography Using High-Efficiency Solid-State Detector Between Men and Women in a Large International Multicenter Study

Circ Cardiovasc Imaging. 2022 Jun;15(6):e012741. doi: 10.1161/CIRCIMAGING.121.012741. Epub 2022 Jun 21.

Abstract

Background: Semiquantitative assessment of stress myocardial perfusion defect has been shown to have greater prognostic value for prediction of major adverse cardiac events (MACE) in women compared with men in single-center studies with conventional single-photon emission computed tomography (SPECT) cameras. We evaluated sex-specific difference in the prognostic value of automated quantification of ischemic total perfusion defect (ITPD) and the interaction between sex and ITPD using high-efficiency SPECT cameras with solid-state detectors in an international multicenter imaging registry (REFINE SPECT [Registry of Fast Myocardial Perfusion Imaging With Next-Generation SPECT]).

Methods: Rest and exercise or pharmacological stress SPECT myocardial perfusion imaging were performed in 17 833 patients from 5 centers. MACE was defined as the first occurrence of death or myocardial infarction. Total perfusion defect (TPD) at rest, stress, and ejection fraction were quantified automatically by software. ITPD was given by stressTPD-restTPD. Cox proportional hazards model was used to evaluate the association between ITPD versus MACE-free survival and expressed as a hazard ratio.

Results: In 10614 men and 7219 women, with a median follow-up of 4.75 years (interquartile range, 3.7-6.1), there were 1709 MACE. In a multivariable Cox model, after adjusting for revascularization and other confounding variables, ITPD was associated with MACE (hazard ratio, 1.08 [95% CI, 1.05-1.1]; P<0.001). There was an interaction between ITPD and sex (P<0.001); predicted survival for ITPD<5% was worse among men compared to women, whereas survival among women was worse than men for ITPD≥5%, P<0.001.

Conclusions: In the international, multicenter REFINE SPECT registry, moderate and severe ischemia as quantified by ITPD from high-efficiency SPECT is associated with a worse prognosis in women compared with men.

Keywords: coronary artery disease; myocardial infarction; myocardial perfusion imaging; prognosis; tomography.

Publication types

  • Multicenter Study
  • Research Support, Non-U.S. Gov't
  • Research Support, N.I.H., Extramural

MeSH terms

  • Coronary Artery Disease*
  • Female
  • Humans
  • Male
  • Myocardial Infarction*
  • Myocardial Perfusion Imaging* / methods
  • Perfusion
  • Prognosis
  • Tomography, Emission-Computed, Single-Photon / methods