Diagnostic accuracy of dynamic CZT-SPECT in coronary artery disease. A systematic review and meta-analysis

J Nucl Cardiol. 2022 Aug;29(4):1686-1697. doi: 10.1007/s12350-021-02721-8. Epub 2021 Aug 4.

Abstract

Background: With the appearance of cadmium-zinc-telluride (CZT) cameras, dynamic myocardial perfusion imaging (MPI) has been introduced, but comparable data to other MPI modalities, such as quantitative coronary angiography (CAG) with fractional flow reserve (FFR) and positron emission tomography (PET), are lacking. This study aimed to evaluate the diagnostic accuracy of dynamic CZT single-photon emission tomography (SPECT) in coronary artery disease compared to quantitative CAG, FFR, and PET as reference.

Materials and methods: Different databases were screened for eligible citations performing dynamic CZT-SPECT against CAG, FFR, or PET. PubMed, OvidSP (Medline), Web of Science, the Cochrane Library, and EMBASE were searched on the 5th of July 2020. Studies had to meet the following pre-established inclusion criteria: randomized controlled trials, retrospective trails or observational studies relevant for the diagnosis of coronary artery disease, and performing CZT-SPECT and within half a year the methodological references. Studies which considered coronary stenosis between 50% and 70% as significant based only on CAG were excluded. Data extracted were sensitivity, specificity, likelihood ratios, and diagnostic odds ratios. Quality was assessed with QUADAS-2 and statistical analysis was performed using a bivariate model.

Results: Based on our criteria, a total of 9 studies containing 421 patients were included. For the assessment of CZT-SPECT, the diagnostic value pooled analysis with a bivariate model was calculated and yielded a sensitivity of 0.79 (% CI 0.73 to 0.85) and a specificity of 0.85 (95% CI 0.74 to 0.92). Diagnostic odds ratio (DOR) was 17.82 (95% CI 8.80 to 36.08, P < 0.001). Positive likelihood ratio (PLR) and negative likelihood ratio (NLR) were 3.86 (95% CI 2.76 to 5.38, P < 0.001) and 0.21 (95% CI 0.13 to 0.33, P < 0.001), respectively.

Conclusion: Based on the results of the current systematic review and meta-analysis, dynamic CZT-SPECT MPI demonstrated a good sensitivity and specificity to diagnose CAD as compared to the gold standards. However, due to the heterogeneity of the methodologies between the CZT-SPECT MPI studies and the relatively small number of included studies, it warrants further well-defined study protocols.

Keywords: Accuracy; CAD; CZT-SPECT; Dynamic flow; Meta-analysis; Systematic review.

Publication types

  • Meta-Analysis
  • Review
  • Systematic Review

MeSH terms

  • Cadmium
  • Coronary Angiography / methods
  • Coronary Artery Disease* / diagnostic imaging
  • Fractional Flow Reserve, Myocardial*
  • Humans
  • Myocardial Perfusion Imaging* / methods
  • Retrospective Studies
  • Tellurium
  • Tomography, Emission-Computed, Single-Photon / methods
  • Tomography, X-Ray Computed
  • Zinc

Substances

  • CdZnTe
  • Cadmium
  • Zinc
  • Tellurium