Predictors of bail-out stenting in patients with small vessel disease treated with drug-coated balloon percutaneous coronary intervention

Catheter Cardiovasc Interv. 2023 Jul;102(1):18-24. doi: 10.1002/ccd.30688. Epub 2023 May 12.

Abstract

Background: Drug-coated balloons (DCBs) have shown comparable results with drug-eluting stents in small vessel disease (SVD) percutaneous coronary intervention (PCI) in terms of target vessel revascularization and a reduced incidence of myocardial infarction. However, the relatively high rate of bail-out stenting (BOS) still represents a major drawback of DCB PCI.

Aims: The aim of the study was to investigate the clinical, anatomic, and procedural features predictive of BOS after DCB PCI in SVD.

Methods: We included all consecutive patients undergoing PCI at our institution between January 2020 and May 2022 who were treated with DCB PCI of a de novo lesion in a coronary vessel with a reference vessel diameter (RVD) between 2.0 and 2.5 mm. Angiographic success was defined as a residual stenosis <30% without flow-limiting dissection. Patients who did not meet these criteria underwent BOS.

Results: A total of 168 consecutive patients and 216 coronary stenoses were included. The rate of bail-out stent was 13.9%. On multivariate analysis, DCB/RVD ratio (odds ratio [OR]: 4.39, 95% confidence interval [CI]: 1.71-11.29, p < 0.01), vessel tortuosity (OR: 7.00, 95% CI: 1.66-29.62, p < 0.01), distal vessel disease (OR: 5.66, 95% CI: 2.02-15.83, p < 0.01), and high complexity (Grade C of ACC/AHA classification) coronary stenoses (OR: 6.31, 95% CI: 1.53-26.04, p = 0.01) were independent predictors of BOS.

Conclusions: BOS is not an infrequent occurrence in DCB PCI of small vessels and is correlated with vessel tortuosity, distal diffuse vessel disease, higher lesion complexity, and balloon diameter oversizing.

Keywords: bail-out stent; de novo percutaneous coronary angioplasty; drug-coated balloons; small vessel disease.

MeSH terms

  • Angioplasty, Balloon, Coronary* / adverse effects
  • Coated Materials, Biocompatible
  • Coronary Angiography / adverse effects
  • Coronary Artery Disease* / complications
  • Coronary Artery Disease* / diagnostic imaging
  • Coronary Artery Disease* / therapy
  • Coronary Restenosis* / etiology
  • Coronary Stenosis* / complications
  • Coronary Stenosis* / diagnostic imaging
  • Coronary Stenosis* / therapy
  • Humans
  • Percutaneous Coronary Intervention* / adverse effects
  • Percutaneous Coronary Intervention* / methods
  • Stents / adverse effects
  • Treatment Outcome
  • Vascular Diseases* / complications

Substances

  • Coated Materials, Biocompatible