A Randomized Comparison of 2 Different Drug-Coated Balloons for In-Stent Restenosis

JACC Cardiovasc Interv. 2023 Apr 10;16(7):759-767. doi: 10.1016/j.jcin.2022.12.018.

Abstract

Background: Although use of drug-coated balloons (DCB) is a promising technique, little is known about the clinical efficacy of the Dissolve DCB in drug-eluting stent (DES) in-stent restenosis (ISR).

Objectives: This study sought to evaluate the efficacy and safety of the Dissolve DCB in patients with DES ISR.

Methods: This was a prospective, multicenter, randomized, noninferiority trial comparing Dissolve DCB with SeQuent Please DCB in patients with DES ISR. Angiographic and clinical follow-up was planned at 9 months in all patients. The primary endpoint was 9-month in-segment late loss.

Results: A total of 260 patients with ISR from 10 Chinese sites were included (Dissolve DCB, n = 128; SeQuent Please DCB, n = 132). Nine-month in-segment late loss was 0.50 ± 0.06 mm with Dissolve DCB vs 0.47 ± 0.07 mm with SeQuent Please DCB; the 1-sided 97.5% upper confidence limit of the difference was 0.18 mm (P for noninferiority = 0.03). Rates of target lesion failure and binary restenosis were numerical higher in the Dissolve DCB cohort compared with the SeQuent Please DCB cohort at 9 months (17.5% vs 10.7%; P = 0.12; 23.4% vs 16.4%; P = 0.19, respectively). At 9 months, major adverse cardiac and cerebrovascular events occurred in 36 patients (28.3%) vs 30 patients (22.9%) in the Dissolve DCB and SeQuent Please DCB groups, respectively.

Conclusions: In this head-to-head randomized trial, the Dissolve DCB was noninferior to the SeQuent Please DCB for 9-month in-segment late loss. However, Dissolve DCB with its numerical increase in target lesion failure and binary restenosis warrants assessment in larger clinical trials (A Safety and Efficacy Study of Dissolve™ in Treatment of Coronary In-Stent Restenosis; NCT03373695).

Keywords: drug-coated balloons; in-stent restenosis; noninferiority trial.

Publication types

  • Randomized Controlled Trial
  • Multicenter Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Angioplasty, Balloon, Coronary* / adverse effects
  • Cardiac Catheters
  • Coated Materials, Biocompatible
  • Constriction, Pathologic / etiology
  • Coronary Angiography
  • Coronary Restenosis* / diagnostic imaging
  • Coronary Restenosis* / etiology
  • Coronary Restenosis* / therapy
  • Drug-Eluting Stents*
  • Humans
  • Paclitaxel / adverse effects
  • Prospective Studies
  • Treatment Outcome

Substances

  • Coated Materials, Biocompatible
  • Paclitaxel

Associated data

  • ClinicalTrials.gov/NCT03373695