Fully automated closed-loop insulin delivery in adults with type 2 diabetes: an open-label, single-center, randomized crossover trial

Nat Med. 2023 Jan;29(1):203-208. doi: 10.1038/s41591-022-02144-z. Epub 2023 Jan 11.

Abstract

In adults with type 2 diabetes, the benefits of fully closed-loop insulin delivery, which does not require meal bolusing, are unclear. In an open-label, single-center, randomized crossover study, 26 adults with type 2 diabetes (7 women and 19 men; (mean ± s.d.) age, 59 ± 11 years; baseline glycated hemoglobin (HbA1c), 75 ± 15 mmol mol-1 (9.0% ± 1.4%)) underwent two 8-week periods to compare the CamAPS HX fully closed-loop app with standard insulin therapy and a masked glucose sensor (control) in random order, with a 2-week to 4-week washout between periods. The primary endpoint was proportion of time in target glucose range (3.9-10.0 mmol l-1). Analysis was by intention to treat. Thirty participants were recruited between 16 December 2020 and 24 November 2021, of whom 28 were randomized to two groups (14 to closed-loop therapy first and 14 to control therapy first). Proportion of time in target glucose range (mean ± s.d.) was 66.3% ± 14.9% with closed-loop therapy versus 32.3% ± 24.7% with control therapy (mean difference, 35.3 percentage points; 95% confidence interval (CI), 28.0-42.6 percentage points; P < 0.001). Time > 10.0 mmol l-1 was 33.2% ± 14.8% with closed-loop therapy versus 67.0% ± 25.2% with control therapy (mean difference, -35.2 percentage points; 95% CI, -42.8 to -27.5 percentage points; P < 0.001). Mean glucose was lower during the closed-loop therapy period than during the control therapy period (9.2 ± 1.2 mmol l-1 versus 12.6 ± 3.0 mmol l-1, respectively; mean difference, -3.6 mmol l-1; 95% CI, -4.6 to -2.5 mmol l-1; P < 0.001). HbA1c was lower following closed-loop therapy (57 ± 9 mmol mol-1 (7.3% ± 0.8%)) than following control therapy (72 ± 13 mmol mol-1 (8.7% ± 1.2%); mean difference, -15 mmol mol-1; 95% CI, -11 to -20 mmol l-1 (mean difference, -1.4%; 95% CI, -1.0 to -1.8%); P < 0.001). Time < 3.9 mmol l-1 was similar between treatments (a median of 0.44% (interquartile range, 0.19-0.81%) during the closed-loop therapy period versus a median of 0.08% (interquartile range, 0.00-1.05%) during the control therapy period; P = 0.43). No severe hypoglycemia events occurred in either period. One treatment-related serious adverse event occurred during the closed-loop therapy period. Fully closed-loop insulin delivery improved glucose control without increasing hypoglycemia compared with standard insulin therapy and may represent a safe and efficacious method to improve outcomes in adults with type 2 diabetes. This study is registered with ClinicalTrials.gov (NCT04701424).

Publication types

  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Blood Glucose
  • Cross-Over Studies
  • Diabetes Mellitus, Type 1* / drug therapy
  • Diabetes Mellitus, Type 2* / drug therapy
  • Female
  • Glycated Hemoglobin
  • Humans
  • Hypoglycemia*
  • Hypoglycemic Agents
  • Insulin
  • Insulin Infusion Systems
  • Male
  • Middle Aged
  • Treatment Outcome

Substances

  • Insulin
  • Blood Glucose
  • Hypoglycemic Agents
  • Glycated Hemoglobin

Associated data

  • ClinicalTrials.gov/NCT04701424