Postimplant Phosphodiesterase-5 Inhibitor Use in Centrifugal Flow Left Ventricular Assist Devices

JACC Heart Fail. 2022 Feb;10(2):89-100. doi: 10.1016/j.jchf.2021.09.008. Epub 2021 Dec 8.

Abstract

Objectives: This study examined the association between phosphodiesterase-5 inhibitor (PDE-5i) use and outcomes in patients with contemporary centrifugal flow left ventricular assist devices (LVADs).

Background: PDE-5i use may affect outcomes in patients with continuous flow LVADs.

Methods: Patients enrolled in INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support), with HeartMate 3 (n = 4,628) or HeartWare Ventricular Assist Device (HVAD) (n = 2,601) implant were included in the analysis. The mean duration of follow-up was 11.94 ± 8.65 months. PDE-5is were used in 2,173 patients. The primary endpoint was the composite of all-cause mortality, ischemic stroke, and pump thrombosis. Propensity matching and stabilized inverse probability of treatment weights were used to adjust for baseline differences between patients receiving and not receiving PDE-5i. Adjusted Cox proportional hazards analysis was performed for each outcome.

Results: The primary endpoint was lower in the PDE-5i group (adjusted HR: 0.77; 95% CI: 0.69-0.86; P < 0.0001; HeartMate 3: adjusted HR: 0.77; 95% CI: 0.64-0.92; P = 0.0044; HVAD: adjusted HR: 0.76; 95% CI: 0.66-0.88; P = 0.0002). All-cause mortality was lower with PDE-5is (adjusted HR: 0.75; 95% CI: 0.65-0.86; P < 0.0001; HeartMate 3: adjusted HR: 0.70; 95% CI: 0.57-0.86; P = 0.0007; HVAD: adjusted HR: 0.78; 95% CI: 0.65-0.94; P = 0.0098) and fewer ischemic strokes with PDE-5is were observed (adjusted HR: 0.71; 95% CI: 0.56-0.89; P = 0.003; HeartMate 3: adjusted HR: 0.67; 95% CI: 0.45-0.99; P = 0.045; HVAD: adjusted HR: 0.73; 95% CI: 0.56-0.97; P = 0.03). LVAD thrombosis was unchanged with PDE-5is, with overall low event rates observed.

Conclusions: Postimplant PDE-5i use was associated with lower mortality and ischemic strokes in patients with centrifugal flow LVADs.

Keywords: all-cause mortality; ischemic stroke; mechanical circulatory support; pharmacotherapy; pump thrombosis.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Cyclic Nucleotide Phosphodiesterases, Type 5
  • Heart Failure*
  • Heart-Assist Devices* / adverse effects
  • Humans
  • Ischemic Stroke*
  • Phosphodiesterase 5 Inhibitors / therapeutic use
  • Retrospective Studies
  • Thrombosis* / etiology